not properly connected
Init bus...
VCC: 3.3 V, VCCQ: 1.8 V
Bus: 1 bit (SDR 24MHz)
Access mode: sector mode
Power supply: dual-voltage (1.70-1.95V, 2.7-3.6V)
Card/BGA: BGA (Discrete embedded) - High density MMC
Manufacturer ID: 0x15 (Samsung)
Product name: RD64MB (0x524436344d42), rev: 0x01, serial number: 0xB32606C8
Manufacturing date: Jan 2018
CID: 15010052 4436344D 4201B326 06C815F0
CSD: D0270132 0F5903FF F6DBFFEF 8E40400C
EXT_CSD revision: 1.8 (MMC v5.1)
Partition info:
Boot1: 4096 KiB
Boot2: 4096 KiB
RPMB: 4096 KiB
User area: 29.12 GiB(31,268,536,320 bytes)
Reading extcsd, size: 512 bytes...
File saved to "\%BACKUPS%\Other\RD64MB_B32606C8\ext_csd.bin" (CRC32: 0xCE215AA😎
Current partition access:
Access to boot partition 1
Reading boot1, size: 4 MiB... Done in 1.567 s
File saved to "\%BACKUPS%\Other\RD64MB_B32606C8\boot1.bin" (CRC32: 0x1147406A)
Blank checking: blank
Current partition access:
Access to boot partition 2
Reading boot2, size: 4 MiB... Done in 1.569 s
File saved to "\%BACKUPS%\Other\RD64MB_B32606C8\boot2.bin" (CRC32: 0x08857DEF)
Blank checking: NOT blank
Current partition access:
Access to user area
Reading userarea, size: 128 MiB... Failed to read block 0x00620000:65536 (return code: 1, CMD Error: Timeout)
cmd response: 0x900, card status: 0x0, card state: 4 (Card is in transfer state)
status: unknown (0)
--- Make sure the connection between BOX and eMMC stable ---
--- please try again (you may RESUME the read process) ---