eMMC Health - Normal or Bad?

Failed entering Smart report mode (return code: 4, CMD Error: Invalid response)
status: A generic card error related to the (and detected during) execution of the last host command

=====================================================================================

Connection status: EHCI:HUB:HUB[#2]:USB 2.00 High-Speed
Interface: UFI High-Speed
Serial number: 0011-8840-5166
Boot version: 1.04, FW version: 1.14 (Aug 25 2021 04:56:05)
Insertion test... Done
Init bus...
VCC: 3.3 V, VCCQ: 3.0 V
Bus: 1 bit (SDR 52MHz)
Access mode: sector mode
Power supply: dual-voltage (1.70-1.95V, 2.7-3.6V)
Card/BGA: BGA (Discrete embedded) - High density MMC
Manufacturer ID: 0x15 (Samsung)
Product name: DH6DAB (0x444836444142), rev: 0x02, serial number: 0x350ECA81
Manufacturing date: Sep 2018
CID: 15010044 48364441 4202350E CA819572
CSD: D0270132 0F5903FF F6DBFFEF 8E40400C
Firmware version: 0x03
EXT_CSD revision: 1.8 (MMC v5.1)
Partition info:
Boot1: 4 MiB
Boot2: 4 MiB
RPMB: 16 MiB
User area: 58.24 GiB(62,537,072,640 bytes)

eMMC 5.x Health report:
Device lifetime: Not Defined
Estimation of the device lifetime (SLC): 10% - 20% device life time used
Estimation of the device lifetime (MLC): 10% - 20% device life time used
Failed entering Smart report mode (return code: 4, CMD Error: Invalid response)
status: A generic card error related to the (and detected during) execution of the last host command

    20 days later
    a month later

    eMMC 5.x HEALTH report:
    Device lifetime: Normal / Not Defined
    Estimation of the device lifetime (SLC): 0% - 10% device life time used
    Estimation of the device lifetime (MLC): 0% - 10% device life time used

    Device Health Report features in eMMC ext_csd rev.1.7 (eMMC 5.0 and above) provides nand flash program/erase cycles information in percentage of useful flash life span.

    Please take a look at the data table below to view eMMC health information by Device life time estimation value and Pre eol info value.

    Now we can conclude, to know the health information of an eMMC 5.0 we use the above two indicators.
    **That is : **

    OK(Health) IC Chip
    Device life time estimation value = 0-50%
    Pre eol info value = Normal
    2018-03-17_222625.jpg
    2018-06-26_165725.jpg

    BAD IC Chip
    Device life time estimation value = above 90%-Exceeded
    Pre eol info value = Urgent
    2018-03-17_222539.jpg

    Hope this little info useful for you
    B.R
    Madgoeslim of UFiXers

    3 years later

    eMMC 5.x Health report:
    Device lifetime: Normal
    Estimation of the device lifetime (SLC): 10% - 20% device life time used
    Estimation of the device lifetime (MLC): 10% - 20% device life time used
    Failed entering Smart report mode (return code: 4, CMD Error: Invalid response)
    status: A generic card error related to the (and detected during) execution of the last host command

      ANSHIMOBILES eMMC 5.x Health report:
      Device lifetime: Normal

      The report says the chip is normal